2,042 research outputs found

    Benchmarking matching color in composite restorations

    Get PDF
    The purpose of this study was to investigate the color samples (A2, A3 and B1) of three different brands of resin composites using dentine masses. 135 discs were prepared (5 plates for each thickness, color and brand of composite material). A colorimetric evaluation, using white and black background, was performed just after preparation. The color was measured corresponding to "Vita" scale and ΔL, Δa, Δb and ΔE values were calculated using a spectrophotometer. The results showed that Value, Chroma and Hue often differ even if the same commercial color and same thickness is used. In conclusion, this study showed that the perfect aesthetics restoration is possible combining individual abilities, experience and correct techniques

    A rare case of melanosis of the hard palate mucosa in a patient with chronic myeloid leukemia

    Get PDF
    Imatinib Mesylate, also known as Gleevec or ST1-571, is a tyrosine-kinase inhibitor used as the gold standard medication for the chronic myeloid leukemia (CML); Imatinib has indeed deeply revolutionized the CML therapy allowing most patients to have a good quality of life. Despite its beneficial effects, Imatinib has significant side effects such as mucosal pigmentation. A 72-year-old female having an Imatinib induced mucosal pigmentation is presented: she has been treated with Imatinib since 2003 and only in 2014 discovered, during a routine dental visit, having a pigmented lesion on her hard palate mucosa. Histopathologically, the lesion shows the deposition of fine dark brown spherical bodies within the lamina propria and cloaked in between the collagen fibers. There was no sign of inflammation, hyperplasia, or hemorrhage in the tissu

    Subcutaneous emphysema during root canal therapy: endodontic accident by sodium hypoclorite

    Get PDF
    Cervicofacial subcutaneous emphysema is defined as the abnormal introduction of air in the subcutaneous tissues of the head and neck. It is mainly caused by trauma, head and neck surgery, general anesthesia, and coughing or habitual performance of Valsalva manoeuvre. The occurrence of subcutaneous emphysema after dental treatment is rare, and diffusion of gas into the mediastinum is much rarer, especially when the procedure is a nonsurgical treatment. Presented here is a case of subcutaneous emphysema that occurred after sodium hypochlorite irrigation during endodontic treatment, and the description of its etiologies and prevention during nonsurgical endodontic treatment. Endodontic success can be essentially achieved via good debridement of a root canal, and an ideal endodontic irrigant is effective in removing the smear layer, opening the dentinal tubules, and producing a clean surface for closer obturation

    Classification review of dental adhesive systems: from the IV generation to the universal type

    Get PDF
    Adhesive dentistry has undergone great progress in the last decades. In light of minimal-invasive dentistry, this new approach promotes a more conservative cavity design, which relies on the effectiveness of current enamel-dentine adhesives. Adhesive dentistry began in 1955 by Buonocore on the benefits of acid etching. With changing technologies, dental adhesives have evolved from no-etch to total-etch (4th and 5th generation) to self-etch (6th, 7th and 8th generation) systems. Currently, bonding to dental substrates is based on three different strategies: 1) etch-and-rinse, 2) self-etch and 3) resin-modified glass-ionomer approach as possessing the unique properties of self-adherence to the tooth tissue. More recently, a new family of dentin adhesives has been introduced (universal or multi-mode adhesives), which may be used either as etch-and-rinse or as self-etch adhesives. The purpose of this article is to review the literature on the current knowledge for each adhesive system according to their classification that have been advocated by many authorities in most operative/restorative procedures. As noted by several valuable studies that have contributed to understanding of bonding to various substrates helps clinicians to choose the appropriate dentin bonding agents for optimal clinical outcomes

    Laser treatment of 13 benign oral vascular lesions by three different surgical techniques

    Get PDF
    Objectives: Benign Oral Vascular Lesions (BOVLs) are a group of vascular diseases characterized by congenital, inflammatory or neoplastic vascular dilations clinically evidenced as more or less wide masses of commonly dark bluish color. If traumatized BOVLs are characterized by a great risk of hemorrhage and their treatment usually requires great caution to prevent massive bleeding. In the last decades lasers have dramatically changed the way of treatment of BOVLs permitting the application of even peculiar techniques that gave interesting advantages in their management reducing hemorrhage risks. The aim of this study was to evaluate the capabilities and disadvantages of three laser assisted techniques in the management of BOVLs. Study design: In this study 13 BOVLs were treated by three different laser techniques: the traditional excisional biopsy (EB), and two less invasive techniques, the transmucosal thermocoagulation (TMT) and the intralesional photocoagulation (ILP). Two different laser devices were adopted in the study: a KTP laser (DEKA, Florence, Italy, 532nm) and a GaAlAs laser (Laser Innovation, Castelgandolfo, Italy, 808nm) selected since their great effectiveness on hemoglobin. Results: In each case, lasers permitted safe treatments of BOVLs without hemorrhages, both during the intervention and in the post-operative period. The minimally invasive techniques (TMT and ILP) permitted even the safe resolution of big lesions without tissue loss. Conclusions: Laser devices confirm to be the gold standard in BOVLs treatment, permitting even the introduction of minimal invasive surgery principles and reducing the risks of hemorrhage typical of these neoplasms. As usual in laser surgery, it is necessary a clear knowledge of the devices and of the laser-tissue interaction to optimize the results reducing risks and disadvantages

    Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study

    Get PDF
    It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws. We also assessed mini-implant insertion failure rate (mini-implant fracture, mini-implants to root contact). A total of 80 taper-shaped mini-implants (Absoanchor® Model SH1312-6; Dentos Inc., Daegu, Korea) 6 mm long with a diameter of 1.1 mm were used. Bone decortication was made before mini-implant insertion by means of three different methods: Group G1: Er:YAG laser (LiteTouch®, Light Instruments, Yokneam, Israel) at energy of 300 mJ, frequency 25 Hz, fluence 38.2 J/cm2, cooling 14 ml/min, tip 1.0 × 17 mm, distance 1 mm, time of irradiation 6 s; Group G2: drill (Hager & Meisinger GmbH, Hansemannstr, Germany); Group G3: piezosurgery (Piezotom Solo, Acteon, NJ, USA). In G4 group (control), mini-implants were driven by a self-drilling method. The primary stability of mini-implants was assessed by measuring damping characteristics between the implant and the tapping head of Periotest device (Gulden-Medizinteknik, Eschenweg, Modautal, Germany). The results in range between − 8 to + 9 allowed immediate loading. Significantly lower Periotest value was found in the control group (mean 0.59 ± 1.57, 95% CI 0.7, 2.4) as compared with Er:YAG laser (mean 4.44 ± 1.64, 95% CI 3.6, 5.3), piezosurgery (mean 17.92 ± 2.73, 95% CI 16.5, 19.3), and a drill (mean 5.91 ± 1.52, 95% CI 5.2, 6.6) (p < 0.05). The highest failure rate (33.3%) during mini-implant insertion was noted for self-drilling method (G4) as compared with G1, G2, and G3 groups (p < 0.05). The small diameter decortication by Er:YAG laser appeared to provide better primary stability as compared to drill and piezosurgery. Decortication of the cortical bone before mini-implant insertion resulted in reduced risk of implant fracture or injury of adjacent teeth. The high initial stability with a smaller diameter of the mini-implant resulted in increased risk of fracture, especially for a self-drilling metho

    Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study

    Get PDF
    It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws. We also assessed mini-implant insertion failure rate (mini-implant fracture, mini-implants to root contact). A total of 80 taper-shaped mini-implants (Absoanchor® Model SH1312-6; Dentos Inc., Daegu, Korea) 6 mm long with a diameter of 1.1 mm were used. Bone decortication was made before mini-implant insertion by means of three different methods: Group G1: Er:YAG laser (LiteTouch®, Light Instruments, Yokneam, Israel) at energy of 300 mJ, frequency 25 Hz, fluence 38.2 J/cm2, cooling 14 ml/min, tip 1.0 × 17 mm, distance 1 mm, time of irradiation 6 s; Group G2: drill (Hager & Meisinger GmbH, Hansemannstr, Germany); Group G3: piezosurgery (Piezotom Solo, Acteon, NJ, USA). In G4 group (control), mini-implants were driven by a self-drilling method. The primary stability of mini-implants was assessed by measuring damping characteristics between the implant and the tapping head of Periotest device (Gulden-Medizinteknik, Eschenweg, Modautal, Germany). The results in range between − 8 to + 9 allowed immediate loading. Significantly lower Periotest value was found in the control group (mean 0.59 ± 1.57, 95% CI 0.7, 2.4) as compared with Er:YAG laser (mean 4.44 ± 1.64, 95% CI 3.6, 5.3), piezosurgery (mean 17.92 ± 2.73, 95% CI 16.5, 19.3), and a drill (mean 5.91 ± 1.52, 95% CI 5.2, 6.6) (p < 0.05). The highest failure rate (33.3%) during mini-implant insertion was noted for self-drilling method (G4) as compared with G1, G2, and G3 groups (p < 0.05). The small diameter decortication by Er:YAG laser appeared to provide better primary stability as compared to drill and piezosurgery. Decortication of the cortical bone before mini-implant insertion resulted in reduced risk of implant fracture or injury of adjacent teeth. The high initial stability with a smaller diameter of the mini-implant resulted in increased risk of fracture, especially for a self-drilling metho

    The antimicrobial photodynamic therapy in the treatment of peri-implantitis

    Get PDF
    The aim of this study is to demonstrate the effectiveness of addition of the antimicrobial photodynamic therapy to the conventional approach in the treatment of peri-implantitis. Materials and Methods. Forty patients were randomly assigned to test or control groups. Patients were assessed at baseline and at six (T1), twelve (T2), and twenty-four (T3) weeks recording plaque index (PlI), probing pocket depth (PPD), and bleeding on probing (BOP); control group received conventional periodontal therapy, while test group received photodynamic therapy in addition to it. Result. Test group showed a 70% reduction in the plaque index values and a 60% reduction in PD values compared to the baseline. BOP and suppuration were not detectable. Control group showed a significative reduction in plaque index and PD. Discussion. Laser therapy has some advantages in comparison to traditional therapy, with faster and greater healing of the wound. Conclusion. Test group showed after 24 weeks a better value in terms of PPD, BOP, and PlI, with an average pocket depth value of 2 mm, if compared with control group (3 mm).Our results suggest that antimicrobial photodynamic therapy with diode laser and phenothiazine chloride represents a reliable adjunctive treatment to conventional therapy. Photodynamic therapy should, however, be considered a coadjuvant in the treatment of peri-implantitis associated with mechanical (scaling) and surgical (grafts) treatments

    Evaluation of wound healing and postoperative pain after oral mucosa laser biopsy with the aid of compound with chlorhexidine and sodium hyaluronate: a randomized double blind clinical trial

    Get PDF
    OBJECTIVES: The aim of this study is to evaluate secondary intention healing process and postoperative pain of oral soft tissues after laser surgery with the use of a compound containing chlorhexidine and sodium hyaluronate. MATERIALS AND METHODS: This double-blind, randomized clinical study included 56 patients affected by benign oral lesions and subjected to excisional biopsy with diode laser and randomly divided into three groups. Study group (SG) received 0.2% chlorhexidine digluconate and 0.2% sodium hyaluronate treatment; control group (CG) received 0.2% chlorhexidine digluconate; and placebo group (PG) followed the same protocol, taking a neutral solution having the same organoleptic characteristics. Wound healing was evaluated using percentage healing index (PHI). Numeric rating scale (NRS) was used to evaluate postoperative pain. RESULTS: PHI (T1 = 7 days) was 67.25% for SG, 58.67% for CG, and 54.55% for PG. PHI (T2 = 14 days) was 94.35% for SG, 77.79% for CG, and 78.98% for PG. A statistically significant difference was between the groups for PHI at T2 p = 0.001. No difference was detectable for pain index. CONCLUSIONS: A solution containing sodium hyaluronate and chlorhexidine is a good support to increase wound healing by secondary intention after laser biopsy, but no differences were in postoperative perception of pain. CLINICAL RELEVANCE: The use of the tested solution can be recommended after laser oral biopsies, to achieve a healing without suture. About the postoperative pain, the compound has not showed the same results and did not have measurable effects
    • …
    corecore